وصف المنتج
1) Permanent magnet motors can maintain high efficiency across a wide speed range, making them particularly suitable for loads such as fans, resulting in significant energy savings. Depending on the cost of energy, the investment cost for the equipment can generally be recovered within 3 to 6 years.
2) The overall weight of the system should not exceed that of the original power transmission system, and should not impose additional burden on the original air cooling island steel structure. It should meet the basic conditions for large-scale retrofitting.
3) Power range: 50kw-150kw
4) Rated speed: 80~120r/min
5) Torque range: 4000~18000N.m
2) The overall weight of the system should not exceed that of the original power transmission system, and should not impose additional burden on the original air cooling island steel structure. It should meet the basic conditions for large-scale retrofitting.
3) Power range: 50kw-150kw
4) Rated speed: 80~120r/min
5) Torque range: 4000~18000N.m
| Parameters | Permanent magnet motor system | Asynchronous motor + Gear Box |
| Rated power(kW) | 132 | |
| Rated torque (N.m) | 15000 | |
| Rated voltage(V) | 380 | |
| Rated speed(r/min) | 81 | |
| Efficiency(%) | 95.26 | 0.93x0.9=0.837 |
| Power factor | 0.9874 | 0.88 |
| Current(A) | 237 | 240 |
| Maximum torque multiple | 2 | 1.5 |
| Weight(t) | 1.7 | 2.6 |